Wednesday, 10 February 2010 11:28 |
|
ECONOLINE system has no thermal break, it is used to construct internal barriers, not only these without opening parts but also with windows and doors.
The width of profiles which is 51 mm ( 6 mm more than standard ones widespread on market ) gives a wide range of possibility for designers and comfort for performers.
The system allows to apply glazing with thicknesses from 3 to 38 mm.
The glazing is fixed and sealed up in sashes by glazing beads with gaskets.
|
|
Read more...
|
|
|
Wednesday, 10 February 2010 11:30 |
|
Three-chambered system designed for constructing external doors and windows.
Applied in profiles thermal break of 24 mm, executed from polyamide glass fibre, considerably improves the mechanical endurance of external and internal chamber of profile..
The thermal brake providesealing thread Coex, which in burning process of varnished profile creates unfailing insulation.Door profiles IMPERIAL possess coefficient of penetration of warmth UR = 2,2 ÷ 2,3 W / m2K.
|
|
Read more...
|
|
Wednesday, 10 February 2010 11:32 |
|
Aluminium system profiles without thermal insulation, mainly destined to interior buildings: boxes, division walls and display cases as well as for sliding doors ( manualy or automaticaly operated), double-acting and smoke hermetic doors. NT 50 allows using of variety of filling: glass, alumonium panels, „sandwich” fillings, panel boards and PVC with 1-40mm.
The structural section depth for frame and sash is 52-60mm.
|
|
Read more...
|
|
|
Wednesday, 10 February 2010 11:35 |
|
The system with thermal insulation is assigned for accomplishing outside building elements rated to the RMG 2.1 material group.
There are plenty of solution for the window and door construction. The application of 16 mm thermal distance piece ensure correct dehydration. The widht of frames and sashes is 52-60mm.
Characteristics of system: precise relation to the Ponzio systems, possibility of installing windows and doors into facade systems,
|
|
Read more...
|
|
Wednesday, 10 February 2010 11:38 |
|
Fire-resistant class (E) The barrier ability to hold the pressure of flames and the hot gases back during definite in classification time expressed in minutes. The flames on heated side can not appear longer than 10 seconds.
Fire isolation (class I) The growth of temperature on non-firing surface of construction can not be higher than 140 Celsius degrees (the average value) and 180 Celsius degrees in one point.
|
|
Read more...
|
|
|
|
|
|
|